*- with 10.1 inch color LCD touch screen, display resolution is 1024*600
*- keyboard, mouse, plug and play
*- the function of temperature compensation (TC)
*In the trend of the seamless display of historical data
*- screen information is stored in the U disk
*Real time data storage function preservation - convenient measurement results
*- automatic instrument operation through USB HOST software upgrade
*In English - optional operation interface
*File operating system - flexible and convenient
*In the WiFi interface for the realization of on-line operation
*- RS232 USB HOST, USB, Device, LAN, and PC can be convenient for data communication and remote control of instruments
Display features:
* use high brightness color 10.1 inch TFT LCD screen, CCFL backlight, clear picture;
* rich display, powerful data search function, status indicator function
* intuitive touch screen operations
* with flashing alarm display, at the same time indicate the lower and lower limit, upper limit and upper limit alarm of all channels;
There are four basic pictures: digital display, bar picture display, real-time curve picture, recall curve and picture
* real time curve recording interval of 1 second ~9999 seconds, step setting, corresponding to the whole screen curve time 30 seconds ~300 minutes
* recall curve intervals are set from 1 second to 9999 seconds
* recall the curve reading cursor function.
Flexible construction:
When more channels are needed, the i/o module can be added
Relay alarm output;
Configurable 8 point change output, photoelectric isolation, the error is less than + 0.2% F • S;
Basic function
* using ARM microprocessor, at the same time to achieve the most 64 signal acquisition, recording, display and alarm
The display accuracy is high, and the basic error is + 0.2% F = S;;
* built in GB2312 Chinese characters library, use Quanpin input method;
* equipped with standard three USB interfaces, with the U disk to transfer the historical data fast and convenient; also access to the keyboard and mouse;
Power supply:
With high-quality brand-name switching power supply, can work in AC power AC 85V~265V wide voltage range;
* provide transmitter, DC, 24V, isolation, distribution;
* through EMCIII level, ensure the instrument work well in bad environment
Input signal
* DC current, DC voltage, thermal resistance, thermocouple, pressure class, select by key input, isolated universal input,
* temperature and pressure compensation supports signal input, constant selection, and provides a variety of compensation models, such as superheated steam, saturated steam, pressure compensation, and other common compensation models;
* DC current: (4~20) mA, (0~10) mA, (0~20) mA
* DC voltage: (1~5) V, (0~5) V (0~10) V, (1~10) V
* thermal resistance: Pt100 (three wire system)
* thermocouples: K, S, R, B, N, E, J, T, cu50
* temperature & humidity: 2305 temperature and humidity probes are available, which can be tested directly (-20 to 110 degrees) (humidity 20% through 98%)
Choose AM2001 humidity module (3%, condition: AT25 degrees C, 60%RH, other conditions are accuracy 5%),
* other input signals or graduation numbers should be indicated when ordering.
Communication and print interface (optional function)
* opto isolation
*RS232 and RS485 standards
* communication rate 96001920057600115200, by setting selection
* supporting test software, providing configuration software and application software technical support
* optional Modbus RTU protocol to communicate with the host computer
* support standard ModBus RTU protocol (optional function), in addition to supporting the company's data management software, but also support the MCGS, king view, and other popular configuration software;
Output:
Relay alarm output; configuration 12 point alarm function.
* configurable 8 point change output, photoelectric isolation, error is less than + 0.2% F = S
Current output (4~20), mA, (0~10) mA, (0~20) mA are optional.
Voltage output (0~5) V, (1~5) V optional.
The factory defaults to (4~20) mA, indicating other types of orders.
Storage: large internal memory 700MB
Support for long, multi-channel recording of large capacity FLASH, you can quickly transfer data from the FLASH to the computer through the U disk. The built-in FLASH has a capacity of 64M bytes and 8 channels if it is recorded once in 20 seconds. It can record 65 days and record the data of all channels as fast as 1 second.
Sampling time measurement of display data files CH=24,
Internal storage
700MB
Display update(minute/div)
30 minute
sampling period(s)
60 sec
Total sampling time
about 12 month
Sample time measurement of event data files CH=24,
internal storage
128MB
sampling period(s)
1 sec
Total sampling time
about 1.5 month
* the standard of the instrument itself is: 2 meters long K thermocouple, temperature range: 0-260 degrees centigrade, and other special requirements, please note before ordering * * can be equipped with different types of intelligent channel board, according to the application requirements.
Analog input module
Model
JK9008
Input type (input point: 8)
Input
range
Test accuracy(integration time 16.7ms or more)
Display resolution
DCV
1~5V
±(0.05% of rdg +3mv)
1mV
Thermo
couple
k
±(0.05% of rdg +0.7℃)
0.1℃
RTO
Pt100
±(0.05% of rdg +0.3℃)
0.1℃
When the measurement period is 100ms, the number of channels may be limited in order to meet the measurement accuracy
Scan interval
100/200/500ms,1/2/5s
Power supply and power waste
Main power supply ,power waste:≤15W
insulation resistance
Between the input loop and the internal loop:≥20MΩ(when 500 VAC)
Withstand voltage
Between the input loop and the internal loop:2500VAC/1 Minute;Between analog input channels: 500VAC/1 minutes (excluding B terminals)
Terminals type
Plug-in Type
Weight
About 0.3kg
Withstand voltage
Between the output loop and the internal loop:3000VAC / Minute
Digital output module
Model
JK9009
Output type(output point:6)
Relay contact
Rated load voltage
100-240VAC OR 5-24VAC
MAX load voltage/current
264VAC OR 26.4VAC、3A/point(resistance load)
Power supply and power waste
Main power supply ,power waste:≤3.5W
insulation resistance
Between the output loop and the internal loop:≥20MΩ(when 500 VAC)
Terminals type
Plug-in Type
Weight
About 0.3kg
Analog multi model input module
Model
JK90M
D input type
(inout point:8 )
DC voltage ,Standard signal,Thermocouple,RTD,DI(Voltage contact),DC current(Connecting external shunt resistance)
Input
input range
Precision of input measurement(The integral time is 18.5mS or more)
Input display resolution
DCV
1~100V
±(0.05% of rdg +3mV)
1mV
Thermocouple
K
±(0.05% of rdg +0.7℃)
0.1℃
RTD
Pt100
±(0.05% of rdg +0.3℃)
0.1℃
When the measurement period is 100ms. To limit the number of channels to meet the measurement accuracy
Scanning interval
1/2/5s
Power and power waste
Mainframe power supply,power waste ≤ 0.6w
Withstand Voltage
Between the re input channel and the internal loop,500VAC /1 minute
Between the Analog input channel,300VAC /1 minute
Terminal type
Pluggable terminal
High speed sampling input module
Model
JK90MG
D input type
(inout point:8 )
DC voltage ,Standard signal,Thermocouple,RTD,DI(Voltage contact),DC current(Connecting external shunt resistance)
Input
input range
Precision of input measurement(The integral time is 18.5mS or more)
Input display resolution
DCV
1~100V
±(0.05% of rdg +3mV)
1mV
Thermocouple
K
±(0.05% of rdg +0.7℃)
0.1℃
RTD
Pt100
±(0.05% of rdg +0.3℃)
0.1℃
When the measurement period is 100ms. To limit the number of channels to meet the measurement accuracy
Scanning interval
100 /200 500mS ,1/2/5s
Power and power waste
Mainframe power supply,power waste ≤ 0.6w
Withstand Voltage
Between the re input channel and the internal loop,500VAC /1 minute
Between the Analog input channel,300VAC /1 minute
Terminal type
Pluggable terminal
Relay output module
Model
JK90C
Scan output type(Output point number:8)
Relay contact (C)
Rated load voltage
100~240VAC or 5~24 VDC
Maximum load voltage / current
264VAC or 26.4 VDC、 3A/point(Resistance load)
Power and power waste
Mainframe power supply,power waste ≤ 1.3w
Withstand Voltage
Between the re input channel and the internal loop,500VAC /1 minute
Between the Analog input channel,300VAC /1 minute
Submit orders
All information in the confirmation page after the check, please click "submit" at the bottom of the page, if enter the settlement of a complete page shows your checkout process has ended, order has generated, in the settlement inflammation of the order page you can also understand the culture order number (it is recommended that you will be inflammation from the order number and customer order number recorded at the same time, in order to "order inquiry"). Instrument mall management system will be your order send Email to confirm your order information.
Reply to order by received payment authorization, JK17 instrument network will complete delivery and accounts processing.
Do order at any time if you want to know, you can query in the "order inquiry" function of your order.
JK17 instrument ? network also prepared fax form of order Goods payment for goods
Customers in Shanghai in order after check, please wait for our delivery.
Customers outside Shanghai, changzhou, please order after check to wire payment or deposit to us, see remittance way remittance way...
more>>
Tel :(+86)4001128155 0519-8556347,89187775
0755-61282381,27467016
Email: mailjk17@126.com
copy Changzhou Jinailian Electronic Technology Co., Ltd 2009 All Rights Reserved.